FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource CodeSystem/FHIR Server from package hl7.terminology#current (62 ms)

Package hl7.terminology
Type CodeSystem
Id Id
FHIR Version R5
Source http://terminology.hl7.org/https://build.fhir.org/ig/HL7/UTG/CodeSystem-v2-0912.html
Url http://terminology.hl7.org/CodeSystem/v2-0912
Version 2.0.0
Status active
Date 2019-12-01
Name Participation
Title participation
Experimental False
Realm uv
Authority hl7
Description HL7-defined code system of concepts that represent functional involvement of a caregiver or member of a care team with an activity being transmitted (e.g., Case Manager, Evaluator, Transcriber, Nurse Care Practitioner, Midwife, Physician Assistant, etc.). Used in HL7 Version 2.x messaging in the PRT segment.
Purpose Underlying Master Code System for V2 table 0912 (Participation)
Copyright This material derives from the HL7 Terminology (THO). THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license.html
Content complete
valueSet http://terminology.hl7.org/ValueSet/v2-0912

Resources that use this resource

ValueSet
v2-0912 hl7VS-participation

Resources that this resource uses

No resources found



Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: CodeSystem v2-0912

Properties

This code system defines the following properties for its concepts

NameCodeURITypeDescription
statusstatushttp://terminology.hl7.org/CodeSystem/utg-concept-properties#statuscodeStatus of the concept
deprecateddeprecatedhttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecatedcodeVersion of HL7 in which the code was deprecated
V2 Concept Commentv2-concCommenthttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentstringV2 Concept Comment
V2 Concept Comment As Publishedv2-concCommentAsPubhttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPubstringV2 Concept Comment As Published
HL7 Concept Usage NotesHL7usageNoteshttp://terminology.hl7.org/CodeSystem/utg-concept-properties#HL7usageNotesstringHL7 Concept Usage Notes

Concepts

This case-sensitive code system http://terminology.hl7.org/CodeSystem/v2-0912 defines the following codes in a Is-A hierarchy:

CodeDisplayDefinitionV2 Concept CommentV2 Concept Comment As PublishedHL7 Concept Usage Notes
AAP Alert Acknowledging ProviderAlert Acknowledging Provider
AC Administration CosignerPerson that cosigned the prescription
AD Admitting ProviderAdmitting ProviderThis role is used in the PRT associated with the PV1 segment, when more information about PV1-17 Admitting doctor is desired.PV1-17 Admitting doctor
AHP Authorized Performing Health ProfessionalThe specific Health Professional who has been approved to perform the ordered services for the patient.This role is used in the PRT associated with the AUT segment, which represents an authorization or a pre-authorization for a referred procedure or requested service by the payor covering the patient's health care. This code is used when the authorization is for a person.
AI Assistant/Alternate InterpreterAssistant/Alternate Interpreter
AP Administering ProviderAdministering ProviderThis role is used in the PRT associated with the RXA segment, when more information about RXA-10 Administering Provider is desired.RXA-10 Administering Provider
APO Authorized Performing Provider OrganizationThe Provider Organization that has been approved to perform the sanctioned procedures to which the patient was referred to.This role is used in the PRT associated with the AUT segment, which represents an authorization or a pre-authorization for a referred procedure or requested service by the payor covering the patient's health care. This code is used when the authorization is for an organization.
ARI Assistant Result InterpreterAssistant Result InterpreterThis role is used in the PRT associated with the OBR segment, where OBR-33 Assistant Result Interpreter has been marked for backwards compatibility only.
AT Attending ProviderAttending ProviderThis role is used in the PRT associated with the PV1 segment, when more information about PV1-7 Attending doctor is desired.PV1-7 Attending doctor
AUT Author/Event InitiatorIdentifies the entity responsible for initiating the eventThis role is used in the PRT associated with the ORC segment, where ORC-19 Action By has been marked for backwards compatibility only.Replaces ORC-19 Action By
CLPO Collecting Provider OrganizationThe organization that is responsible for collecting the specimen.This role is used in the PRT associated with the OBR segment, where OBR-10 Collector Identifier, when intended to convey the organization information, has been marked for backwards compatibility only.
CP Consulting ProviderConsulting Provider
DIE De-Identification EntityOrganization, person or device that has the authority to remove a specimen identifier.
DP Dispensing ProviderDispensing ProviderThis role is used in the PRT associated with the RXD segment, where RXD-10 Dispensing Provider has been marked for backwards compatibility only.RXD-10 Dispensing Provider
EARI Expected Assistant Result InterpreterThe Assistant Result Interpreter who is expected to interpret the result (in the future).This will support filtering orders into the correct work queue of the Assistant Result Interpreter.
ED Entering DeviceIdentifies the device that was used to enter the order into the system.This role is used in the PRT associated with the ORC segment, where ORC-18 Entering Device has been marked for backwards compatibility only.
EO Entering OrganizationIdentifies the organization that entered the order into the system.This role is used in the PRT associated with the ORC segment, where ORC-17 Entering Organization has been marked for backwards compatibility only.
EP Entering PersonIdentifies the person that entered the order into the systemReplaces ORC-10 Entered ByReplaces ORC-10 Entered By
EPRI Expected Principal Result InterpreterThe Principal Result Interpreter who is expected to interpret the result (in the future).This will support filtering orders into the correct work queue of the Principal Result Interpreter.
EQUIP EquipmentEquipmentThis role is used in the PRT associated with the OBX segment, where OBX-18 Equipment Instance Identifier has been marked for backwards compatibility only.
FHCP Family Health Care ProfessionalFamily Health Care Professional
FL From LocationDescribes the location (coordinates) of the specimen/container in the previous holder / storage equipment before the move or the geographical location from which the specimen/container was moved.
MDIR Medical DirectorMedical DirectorOBX-25 Performing Organization Medical Director
OF Ordering FacilityThe facility from where the order was placedThis role is used in the PRT associated with the ORC segment, where ORC-21 Ordering Facility Name, ORC-22 Ordering Facility Address and ORC-23 Ordering Facility Phone Number have been marked for backwards compatibility only.
OP Ordering ProviderOrdering ProviderThis role is used in the PRT associated with either the ORC segment, where ORC-12 Ordering Provider, OBR-16 Ordering Provider, ORC-24 Ordering Provider Address have been marked for backwards compatibility only, or the OBR segment, where OBR-16 Ordering Provider has been marked for backwards compatibility only; the RXO segment, when more information about RXO-14 Ordering Provider's DEA Number is desired; the RXE segment, where RXE-13 Ordering Provider's DEA Number has been marked for backwards compatibility only.ORC-12 Ordering Provider, OBR-16 Ordering Provider, RXO-14 Ordering Provider's DEA Number, RXE-13 Ordering Provider's DEA Number, ORC-24 Ordering Provider Address
OPO Ordering Provider OrganizationThe organization the ordering provider is associated with.This code is broader than Referring Provider Organization (RPO); it can be used for inter and intra-organizational orders.
OS Outside Site(s) Where Observation May Be PerformedOutside Site(s) Where Observation May Be PerformedThis role is used in the PRT associated with the OM1 segment, where OM1-27 Outside Site(s) Where Observation May Be Performed has been deprecated.Replacing OM1-27 Outside Site(s) Where Observation May Be Performed
PB Packed byPacked by
PH PharmacistIdentifies the person taking responsibility for the prescription dispenseThis role is used in the PRT associated with the RXE segment, where RXE-14 Pharmacist/Treatment Supplier's Verifier ID has been marked for backwards compatibility only.Replaces RXE-14 Pharmacist/Treatment Supplier's Verifier ID
PI Primary InterpreterPrimary Interpreter
PO Performing OrganizationPerforming Organization
POMD Performing Organization Medical DirectorPerforming Organization Medical DirectorThis role is used in the PRT associated with the OBX segment, where OBX-25 Performing Organization Medical Director has been marked for backwards compatibility only
PP Primary Care ProviderPrimary Care Provider
PPH Patient Preferred PharmacyPharmacy the patient would prefer to use for any future medication orders.When a patient registers, this allows a system to indicate the default pharmacy to which the provider should send prescribed medication orders.Most likely to be used in ADT messages for outpatient care.
PRI Principal Result InterpreterIdentifies the person responsible for interpreting the results of the study/testThis role is used in the PRT associated with the OBR segment, where OBR-32 Principal Result Interpreter has been marked for backwards compatibility only.
RCT Results Copies ToResults Copies To
RHP Referring Health ProfessionalThe Health Professional who refers the patient.
RIE Re-Identification EntityOrganization, person or device that has the authority to assign a specimen identifier.
RO Responsible ObserverResponsible ObserverThis role is used in the PRT associated with the OBX segment, where OBX-16 Responsible Observer has been marked for backwards compatibility onlyOBX-16 Responsible Observer
RP Referring ProviderReferring ProviderThis role is used in the PRT associated with the PV1 segment, when more information about PV1-8 Referring doctor is desired.PV1-8 Referring doctor
RPO Referring Provider OrganizationThe Provider Organization that refers the patient.
RT Referred to ProviderReferred to Provider
SB Send bySend by
SC Specimen CollectorThe person that collected the specimen.This role is used in the PRT associated with the OBR segment, where OBR-10 Collector Identifier, when intended to convey person information, has been marked for backwards compatibility onlyOBR-10 Collector Identifier
TL To LocationDescribes the location (coordinates) of the specimen/container in the previous holder / storage equipment after the move or the geographical location to which the specimen/container was moved.
TN TechnicianTechnicianThis role is used in the PRT associated with the OBR segment, where OBR-34 Technician has been marked for backwards compatibility only
TR TranscriptionistTranscriptionistThis role is used in the PRT associated with the OBR segment, where OBR-35 Transcriptionist has been marked for backwards compatibility only
VP Verifier (Verifying Person)Identifies the person verifying the dispense / a step in the dispense process / verifying the treatment corresponds to the orderThis role is used in the PRT associated with the ORC segment, where Replaces ORC-11 Verified By has been marked for backwards compatibility onlyReplaces ORC-11 Verified By
VPS Verifying Pharmaceutical Supplier (not sure how to dissect Pharmacist/Treatment Supplier's Verifier ID)Verifying Pharmaceutical Supplier (not sure how to dissect Pharmacist/Treatment Supplier's Verifier ID)RXE-14 Pharmacist/Treatment Supplier's Verifier IDUse of this code is deprecated; depending on the role of the person use either PH or VP.
VTS Verifying Treatment Supplier (not sure how to dissect Pharmacist/Treatment Supplier's Verifier ID)Verifying Treatment Supplier (not sure how to dissect Pharmacist/Treatment Supplier's Verifier ID)RXE-14 Pharmacist/Treatment Supplier's Verifier IDUse of this code is deprecated; depending on the role of the person use either PH or VP.
WAY WaypointWaypoint
WAYR Waypoint RecipientWaypoint Recipient

Source

{
  "resourceType" : "CodeSystem",
  "id" : "v2-0912",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: CodeSystem v2-0912</b></p><a name=\"v2-0912\"> </a><a name=\"hcv2-0912\"> </a><a name=\"v2-0912-en-US\"> </a><p><b>Properties</b></p><p><b>This code system defines the following properties for its concepts</b></p><table class=\"grid\"><tr><td><b>Name</b></td><td><b>Code</b></td><td><b>URI</b></td><td><b>Type</b></td><td><b>Description</b></td></tr><tr><td>status</td><td>status</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#status</td><td>code</td><td>Status of the concept</td></tr><tr><td>deprecated</td><td>deprecated</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated</td><td>code</td><td>Version of HL7 in which the code was deprecated</td></tr><tr><td>V2 Concept Comment</td><td>v2-concComment</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment</td><td>string</td><td>V2 Concept Comment</td></tr><tr><td>V2 Concept Comment As Published</td><td>v2-concCommentAsPub</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPub</td><td>string</td><td>V2 Concept Comment As Published</td></tr><tr><td>HL7 Concept Usage Notes</td><td>HL7usageNotes</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#HL7usageNotes</td><td>string</td><td>HL7 Concept Usage Notes</td></tr></table><p><b>Concepts</b></p><p>This case-sensitive code system <code>http://terminology.hl7.org/CodeSystem/v2-0912</code> defines the following codes in a Is-A hierarchy:</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td><td><b>V2 Concept Comment</b></td><td><b>V2 Concept Comment As Published</b></td><td><b>HL7 Concept Usage Notes</b></td></tr><tr><td style=\"white-space:nowrap\">AAP<a name=\"v2-0912-AAP\"> </a></td><td>Alert Acknowledging Provider</td><td>Alert Acknowledging Provider</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">AC<a name=\"v2-0912-AC\"> </a></td><td>Administration Cosigner</td><td>Person that cosigned the prescription</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">AD<a name=\"v2-0912-AD\"> </a></td><td>Admitting Provider</td><td>Admitting Provider</td><td>This role is used in the PRT associated with the PV1 segment, when more information about PV1-17 Admitting doctor is desired.</td><td>PV1-17 Admitting doctor</td><td/></tr><tr><td style=\"white-space:nowrap\">AHP<a name=\"v2-0912-AHP\"> </a></td><td>Authorized Performing Health Professional</td><td>The specific Health Professional who has been approved to perform the ordered services for the patient.</td><td>This role is used in the PRT associated with the AUT segment, which represents an authorization or a pre-authorization for a referred procedure or requested service by the payor covering the patient's health care. This code is used when the authorization is for a person.</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">AI<a name=\"v2-0912-AI\"> </a></td><td>Assistant/Alternate Interpreter</td><td>Assistant/Alternate Interpreter</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">AP<a name=\"v2-0912-AP\"> </a></td><td>Administering Provider</td><td>Administering Provider</td><td>This role is used in the PRT associated with the RXA segment, when more information about RXA-10 Administering Provider is desired.</td><td>RXA-10 Administering Provider</td><td/></tr><tr><td style=\"white-space:nowrap\">APO<a name=\"v2-0912-APO\"> </a></td><td>Authorized Performing Provider Organization</td><td>The Provider Organization that has been approved to perform the sanctioned procedures to which the patient was referred to.</td><td>This role is used in the PRT associated with the AUT segment, which represents an authorization or a pre-authorization for a referred procedure or requested service by the payor covering the patient's health care. This code is used when the authorization is for an organization.</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">ARI<a name=\"v2-0912-ARI\"> </a></td><td>Assistant Result Interpreter</td><td>Assistant Result Interpreter</td><td>This role is used in the PRT associated with the OBR segment, where OBR-33 Assistant Result Interpreter has been marked for backwards compatibility only.</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">AT<a name=\"v2-0912-AT\"> </a></td><td>Attending Provider</td><td>Attending Provider</td><td>This role is used in the PRT associated with the PV1 segment, when more information about \r\n PV1-7 Attending doctor is desired.</td><td>PV1-7 Attending doctor</td><td/></tr><tr><td style=\"white-space:nowrap\">AUT<a name=\"v2-0912-AUT\"> </a></td><td>Author/Event Initiator</td><td>Identifies the entity responsible for initiating the event</td><td>This role is used in the PRT associated with the ORC segment, where ORC-19 Action By has been marked for backwards compatibility only.</td><td>Replaces ORC-19 Action By</td><td/></tr><tr><td style=\"white-space:nowrap\">CLPO<a name=\"v2-0912-CLPO\"> </a></td><td>Collecting Provider Organization</td><td>The organization that is responsible for collecting the specimen.</td><td>This role is used in the PRT associated with the OBR segment, where OBR-10 Collector Identifier, when intended to convey the organization information, has been marked for backwards compatibility only.</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">CP<a name=\"v2-0912-CP\"> </a></td><td>Consulting Provider</td><td>Consulting Provider</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">DIE<a name=\"v2-0912-DIE\"> </a></td><td>De-Identification Entity</td><td>Organization, person or device that has the authority to remove a specimen identifier.</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">DP<a name=\"v2-0912-DP\"> </a></td><td>Dispensing Provider</td><td>Dispensing Provider</td><td>This role is used in the PRT associated with the RXD segment, where RXD-10 Dispensing Provider has been marked for backwards compatibility only.</td><td>RXD-10 Dispensing Provider</td><td/></tr><tr><td style=\"white-space:nowrap\">EARI<a name=\"v2-0912-EARI\"> </a></td><td>Expected Assistant Result Interpreter</td><td>The Assistant Result Interpreter who is expected to interpret the result (in the future).</td><td>This will support filtering orders into the correct work queue of the Assistant Result Interpreter.</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">ED<a name=\"v2-0912-ED\"> </a></td><td>Entering Device</td><td>Identifies the device that was used to enter the order into the system.</td><td>This role is used in the PRT associated with the ORC segment, where ORC-18 Entering Device has been marked for backwards compatibility only.</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">EO<a name=\"v2-0912-EO\"> </a></td><td>Entering Organization</td><td>Identifies the organization that entered the order into the system.</td><td>This role is used in the PRT associated with the ORC segment, where ORC-17 Entering Organization has been marked for backwards compatibility only.</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">EP<a name=\"v2-0912-EP\"> </a></td><td>Entering Person</td><td>Identifies the person that entered the order into the system</td><td>Replaces ORC-10 Entered By</td><td>Replaces ORC-10 Entered By</td><td/></tr><tr><td style=\"white-space:nowrap\">EPRI<a name=\"v2-0912-EPRI\"> </a></td><td>Expected Principal Result Interpreter</td><td>The Principal Result Interpreter who is expected to interpret the result (in the future).</td><td>This will support filtering orders into the correct work queue of the Principal Result Interpreter.</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">EQUIP<a name=\"v2-0912-EQUIP\"> </a></td><td>Equipment</td><td>Equipment</td><td>This role is used in the PRT associated with the OBX segment, where OBX-18 Equipment Instance Identifier has been marked for backwards compatibility only.</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">FHCP<a name=\"v2-0912-FHCP\"> </a></td><td>Family Health Care Professional</td><td>Family Health Care Professional</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">FL<a name=\"v2-0912-FL\"> </a></td><td>From Location</td><td>Describes the location (coordinates) of the specimen/container in the previous holder / storage equipment before the move or the geographical location from which the specimen/container was moved.</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">MDIR<a name=\"v2-0912-MDIR\"> </a></td><td>Medical Director</td><td>Medical Director</td><td/><td>OBX-25 Performing Organization Medical Director</td><td/></tr><tr><td style=\"white-space:nowrap\">OF<a name=\"v2-0912-OF\"> </a></td><td>Ordering Facility</td><td>The facility from where the order was placed</td><td>This role is used in the PRT associated with the ORC segment, where ORC-21 Ordering Facility Name, ORC-22 Ordering Facility Address and ORC-23 Ordering Facility Phone Number have been marked for backwards compatibility only.</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">OP<a name=\"v2-0912-OP\"> </a></td><td>Ordering Provider</td><td>Ordering Provider</td><td>This role is used in the PRT associated with either the ORC segment, where ORC-12 Ordering Provider, OBR-16 Ordering Provider, ORC-24 Ordering Provider Address have been marked for backwards compatibility only, or the OBR segment, where OBR-16 Ordering Provider has been marked for backwards compatibility only; the RXO segment, when more information about RXO-14 Ordering Provider's DEA Number is desired; the RXE segment, where RXE-13 Ordering Provider's DEA Number has been marked for backwards compatibility only.</td><td>ORC-12 Ordering Provider, OBR-16 Ordering Provider, RXO-14 Ordering Provider's DEA Number, RXE-13 Ordering Provider's DEA Number, ORC-24 Ordering Provider Address</td><td/></tr><tr><td style=\"white-space:nowrap\">OPO<a name=\"v2-0912-OPO\"> </a></td><td>Ordering Provider Organization</td><td>The organization the ordering provider is associated with.</td><td>This code is broader than Referring Provider Organization (RPO); it can be used for inter and intra-organizational orders.</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">OS<a name=\"v2-0912-OS\"> </a></td><td>Outside Site(s) Where Observation May Be Performed</td><td>Outside Site(s) Where Observation May Be Performed</td><td>This role is used in the PRT associated with the OM1 segment, where OM1-27 Outside Site(s) Where Observation May Be Performed has been deprecated.</td><td>Replacing OM1-27 Outside Site(s) Where Observation May Be Performed</td><td/></tr><tr><td style=\"white-space:nowrap\">PB<a name=\"v2-0912-PB\"> </a></td><td>Packed by</td><td>Packed by</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">PH<a name=\"v2-0912-PH\"> </a></td><td>Pharmacist</td><td>Identifies the person taking responsibility for the prescription dispense</td><td>This role is used in the PRT associated with the RXE segment, where RXE-14 Pharmacist/Treatment Supplier's Verifier ID has been marked for backwards compatibility only.</td><td>Replaces RXE-14 Pharmacist/Treatment Supplier's Verifier ID</td><td/></tr><tr><td style=\"white-space:nowrap\">PI<a name=\"v2-0912-PI\"> </a></td><td>Primary Interpreter</td><td>Primary Interpreter</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">PO<a name=\"v2-0912-PO\"> </a></td><td>Performing Organization</td><td>Performing Organization</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">POMD<a name=\"v2-0912-POMD\"> </a></td><td>Performing Organization Medical Director</td><td>Performing Organization Medical Director</td><td>This role is used in the PRT associated with the OBX segment, where OBX-25 Performing Organization Medical Director has been marked for backwards compatibility only</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">PP<a name=\"v2-0912-PP\"> </a></td><td>Primary Care Provider</td><td>Primary Care Provider</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">PPH<a name=\"v2-0912-PPH\"> </a></td><td>Patient Preferred Pharmacy</td><td>Pharmacy the patient would prefer to use for any future medication orders.</td><td>When a patient registers, this allows a system to indicate the default pharmacy to which the provider should send prescribed medication orders.</td><td/><td>Most likely to be used in ADT messages for outpatient care.</td></tr><tr><td style=\"white-space:nowrap\">PRI<a name=\"v2-0912-PRI\"> </a></td><td>Principal Result Interpreter</td><td>Identifies the person responsible for interpreting the results of the study/test</td><td>This role is used in the PRT associated with the OBR segment, where OBR-32 Principal Result Interpreter has been marked for backwards compatibility only.</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">RCT<a name=\"v2-0912-RCT\"> </a></td><td>Results Copies To</td><td>Results Copies To</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">RHP<a name=\"v2-0912-RHP\"> </a></td><td>Referring Health Professional</td><td>The Health Professional who refers the patient.</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">RIE<a name=\"v2-0912-RIE\"> </a></td><td>Re-Identification Entity</td><td>Organization, person or device that has the authority to assign a specimen identifier.</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">RO<a name=\"v2-0912-RO\"> </a></td><td>Responsible Observer</td><td>Responsible Observer</td><td>This role is used in the PRT associated with the OBX segment, where OBX-16 Responsible Observer has been marked for backwards compatibility only</td><td>OBX-16 Responsible Observer</td><td/></tr><tr><td style=\"white-space:nowrap\">RP<a name=\"v2-0912-RP\"> </a></td><td>Referring Provider</td><td>Referring Provider</td><td>This role is used in the PRT associated with the PV1 segment, when more information about PV1-8 Referring doctor is desired.</td><td>PV1-8 Referring doctor</td><td/></tr><tr><td style=\"white-space:nowrap\">RPO<a name=\"v2-0912-RPO\"> </a></td><td>Referring Provider Organization</td><td>The Provider Organization that refers the patient.</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">RT<a name=\"v2-0912-RT\"> </a></td><td>Referred to Provider</td><td>Referred to Provider</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">SB<a name=\"v2-0912-SB\"> </a></td><td>Send by</td><td>Send by</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">SC<a name=\"v2-0912-SC\"> </a></td><td>Specimen Collector</td><td>The person that collected the specimen.</td><td>This role is used in the PRT associated with the OBR segment, where OBR-10 Collector Identifier, when intended to convey person information, has been marked for backwards compatibility only</td><td>OBR-10 Collector Identifier</td><td/></tr><tr><td style=\"white-space:nowrap\">TL<a name=\"v2-0912-TL\"> </a></td><td>To Location</td><td>Describes the location (coordinates) of the specimen/container in the previous holder / storage equipment after the move or the geographical location to which the specimen/container was moved.</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">TN<a name=\"v2-0912-TN\"> </a></td><td>Technician</td><td>Technician</td><td>This role is used in the PRT associated with the OBR segment, where OBR-34 Technician has been marked for backwards compatibility only</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">TR<a name=\"v2-0912-TR\"> </a></td><td>Transcriptionist</td><td>Transcriptionist</td><td>This role is used in the PRT associated with the OBR segment, where OBR-35 Transcriptionist has been marked for backwards compatibility only</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">VP<a name=\"v2-0912-VP\"> </a></td><td>Verifier (Verifying Person)</td><td>Identifies the person verifying the dispense / a step in the dispense process / verifying the treatment corresponds to the order</td><td>This role is used in the PRT associated with the ORC segment, where Replaces ORC-11 Verified By has been marked for backwards compatibility only</td><td>Replaces ORC-11 Verified By</td><td/></tr><tr><td style=\"white-space:nowrap\">VPS<a name=\"v2-0912-VPS\"> </a></td><td>Verifying Pharmaceutical Supplier (not sure how to dissect Pharmacist/Treatment Supplier's Verifier ID)</td><td>Verifying Pharmaceutical Supplier (not sure how to dissect Pharmacist/Treatment Supplier's Verifier ID)</td><td/><td>RXE-14 Pharmacist/Treatment Supplier's Verifier ID</td><td>Use of this code is deprecated; depending on the role of the person use either PH or VP.</td></tr><tr><td style=\"white-space:nowrap\">VTS<a name=\"v2-0912-VTS\"> </a></td><td>Verifying Treatment Supplier (not sure how to dissect Pharmacist/Treatment Supplier's Verifier ID)</td><td>Verifying Treatment Supplier (not sure how to dissect Pharmacist/Treatment Supplier's Verifier ID)</td><td/><td>RXE-14 Pharmacist/Treatment Supplier's Verifier ID</td><td>Use of this code is deprecated; depending on the role of the person use either PH or VP.</td></tr><tr><td style=\"white-space:nowrap\">WAY<a name=\"v2-0912-WAY\"> </a></td><td>Waypoint</td><td>Waypoint</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">WAYR<a name=\"v2-0912-WAYR\"> </a></td><td>Waypoint Recipient</td><td>Waypoint Recipient</td><td/><td/><td/></tr></table></div>"
  },
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode" : "oo"
    }
  ],
  "url" : "http://terminology.hl7.org/CodeSystem/v2-0912",
  "identifier" : [
    {
      "system" : "urn:ietf:rfc:3986",
      "value" : "urn:oid:2.16.840.1.113883.18.420"
    }
  ],
  "version" : "2.0.0",
  "name" : "Participation",
  "title" : "participation",
  "status" : "active",
  "experimental" : false,
  "date" : "2019-12-01",
  "publisher" : "Health Level Seven International",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://hl7.org"
        },
        {
          "system" : "email",
          "value" : "hq@HL7.org"
        }
      ]
    }
  ],
  "description" : "HL7-defined code system of concepts that represent functional involvement of a caregiver or member of a care team with an activity being transmitted (e.g., Case Manager, Evaluator, Transcriber, Nurse Care Practitioner, Midwife, Physician Assistant, etc.). Used in HL7 Version 2.x messaging in the PRT segment.",
  "purpose" : "Underlying Master Code System for V2 table 0912 (Participation)",
  "copyright" : "This material derives from the HL7 Terminology (THO). THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license.html",
  "caseSensitive" : true,
  "valueSet" : "http://terminology.hl7.org/ValueSet/v2-0912",
  "hierarchyMeaning" : "is-a",
  "compositional" : false,
  "versionNeeded" : false,
  "content" : "complete",
  "property" : [
    {
      "code" : "status",
      "uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#status",
      "description" : "Status of the concept",
      "type" : "code"
    },
    {
      "code" : "deprecated",
      "uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated",
      "description" : "Version of HL7 in which the code was deprecated",
      "type" : "code"
    },
    {
      "code" : "v2-concComment",
      "uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment",
      "description" : "V2 Concept Comment",
      "type" : "string"
    },
    {
      "code" : "v2-concCommentAsPub",
      "uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPub",
      "description" : "V2 Concept Comment As Published",
      "type" : "string"
    },
    {
      "code" : "HL7usageNotes",
      "uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#HL7usageNotes",
      "description" : "HL7 Concept Usage Notes",
      "type" : "string"
    }
  ],
  "concept" : [
    {
      "id" : "6567",
      "code" : "AAP",
      "display" : "Alert Acknowledging Provider",
      "definition" : "Alert Acknowledging Provider",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6568",
      "code" : "AC",
      "display" : "Administration Cosigner",
      "definition" : "Person that cosigned the prescription",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6569",
      "code" : "AD",
      "display" : "Admitting Provider",
      "definition" : "Admitting Provider",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the PV1 segment, when more information about PV1-17 Admitting doctor is desired."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "PV1-17 Admitting doctor"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6570",
      "code" : "AHP",
      "display" : "Authorized Performing Health Professional",
      "definition" : "The specific Health Professional who has been approved to perform the ordered services for the patient.",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the AUT segment, which represents an authorization or a pre-authorization for a referred procedure or requested service by the payor covering the patient's health care. This code is used when the authorization is for a person."
        },
        {
          "code" : "status",
          "valueCode" : "N"
        }
      ]
    },
    {
      "id" : "6571",
      "code" : "AI",
      "display" : "Assistant/Alternate Interpreter",
      "definition" : "Assistant/Alternate Interpreter",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6572",
      "code" : "AP",
      "display" : "Administering Provider",
      "definition" : "Administering Provider",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the RXA segment, when more information about RXA-10 Administering Provider is desired."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "RXA-10 Administering Provider"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6573",
      "code" : "APO",
      "display" : "Authorized Performing Provider Organization",
      "definition" : "The Provider Organization that has been approved to perform the sanctioned procedures to which the patient was referred to.",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the AUT segment, which represents an authorization or a pre-authorization for a referred procedure or requested service by the payor covering the patient's health care. This code is used when the authorization is for an organization."
        },
        {
          "code" : "status",
          "valueCode" : "N"
        }
      ]
    },
    {
      "id" : "6574",
      "code" : "ARI",
      "display" : "Assistant Result Interpreter",
      "definition" : "Assistant Result Interpreter",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the OBR segment, where OBR-33 Assistant Result Interpreter has been marked for backwards compatibility only."
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6575",
      "code" : "AT",
      "display" : "Attending Provider",
      "definition" : "Attending Provider",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the PV1 segment, when more information about \r\n PV1-7 Attending doctor is desired."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "PV1-7 Attending doctor"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6576",
      "code" : "AUT",
      "display" : "Author/Event Initiator",
      "definition" : "Identifies the entity responsible for initiating the event",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the ORC segment, where ORC-19 Action By has been marked for backwards compatibility only."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Replaces ORC-19 Action By"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6577",
      "code" : "CLPO",
      "display" : "Collecting Provider Organization",
      "definition" : "The organization that is responsible for collecting the specimen.",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the OBR segment, where OBR-10 Collector Identifier, when intended to convey the organization information, has been marked for backwards compatibility only."
        },
        {
          "code" : "status",
          "valueCode" : "N"
        }
      ]
    },
    {
      "id" : "6578",
      "code" : "CP",
      "display" : "Consulting Provider",
      "definition" : "Consulting Provider",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6579",
      "code" : "DIE",
      "display" : "De-Identification Entity",
      "definition" : "Organization, person or device that has the authority to remove a specimen identifier.",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "N"
        }
      ]
    },
    {
      "id" : "6580",
      "code" : "DP",
      "display" : "Dispensing Provider",
      "definition" : "Dispensing Provider",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the RXD segment, where RXD-10 Dispensing Provider has been marked for backwards compatibility only."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "RXD-10 Dispensing Provider"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6581",
      "code" : "EARI",
      "display" : "Expected Assistant Result Interpreter",
      "definition" : "The Assistant Result Interpreter who is expected to interpret the result (in the future).",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This will support filtering orders into the correct work queue of the Assistant Result Interpreter."
        },
        {
          "code" : "status",
          "valueCode" : "N"
        }
      ]
    },
    {
      "id" : "6582",
      "code" : "ED",
      "display" : "Entering Device",
      "definition" : "Identifies the device that was used to enter the order into the system.",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the ORC segment, where ORC-18 Entering Device has been marked for backwards compatibility only."
        },
        {
          "code" : "status",
          "valueCode" : "N"
        }
      ]
    },
    {
      "id" : "6583",
      "code" : "EO",
      "display" : "Entering Organization",
      "definition" : "Identifies the organization that entered the order into the system.",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the ORC segment, where ORC-17 Entering Organization has been marked for backwards compatibility only."
        },
        {
          "code" : "status",
          "valueCode" : "N"
        }
      ]
    },
    {
      "id" : "6584",
      "code" : "EP",
      "display" : "Entering Person",
      "definition" : "Identifies the person that entered the order into the system",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "Replaces ORC-10 Entered By"
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Replaces ORC-10 Entered By"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6585",
      "code" : "EPRI",
      "display" : "Expected Principal Result Interpreter",
      "definition" : "The Principal Result Interpreter who is expected to interpret the result (in the future).",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This will support filtering orders into the correct work queue of the Principal Result Interpreter."
        },
        {
          "code" : "status",
          "valueCode" : "N"
        }
      ]
    },
    {
      "id" : "6586",
      "code" : "EQUIP",
      "display" : "Equipment",
      "definition" : "Equipment",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the OBX segment, where OBX-18 Equipment Instance Identifier has been marked for backwards compatibility only."
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6587",
      "code" : "FHCP",
      "display" : "Family Health Care Professional",
      "definition" : "Family Health Care Professional",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6588",
      "code" : "FL",
      "display" : "From Location",
      "definition" : "Describes the location (coordinates) of the specimen/container in the previous holder / storage equipment before the move or the geographical location from which the specimen/container was moved.",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "N"
        }
      ]
    },
    {
      "id" : "6589",
      "code" : "MDIR",
      "display" : "Medical Director",
      "definition" : "Medical Director",
      "property" : [
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "OBX-25 Performing Organization Medical Director"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6590",
      "code" : "OF",
      "display" : "Ordering Facility",
      "definition" : "The facility from where the order was placed",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the ORC segment, where ORC-21 Ordering Facility Name, ORC-22 Ordering Facility Address and ORC-23 Ordering Facility Phone Number have been marked for backwards compatibility only."
        },
        {
          "code" : "status",
          "valueCode" : "N"
        }
      ]
    },
    {
      "id" : "6591",
      "code" : "OP",
      "display" : "Ordering Provider",
      "definition" : "Ordering Provider",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with either the ORC segment, where ORC-12 Ordering Provider, OBR-16 Ordering Provider, ORC-24 Ordering Provider Address have been marked for backwards compatibility only, or the OBR segment, where OBR-16 Ordering Provider has been marked for backwards compatibility only; the RXO segment, when more information about RXO-14 Ordering Provider's DEA Number is desired; the RXE segment, where RXE-13 Ordering Provider's DEA Number has been marked for backwards compatibility only."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "ORC-12 Ordering Provider, OBR-16 Ordering Provider, RXO-14 Ordering Provider's DEA Number, RXE-13 Ordering Provider's DEA Number, ORC-24 Ordering Provider Address"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6592",
      "code" : "OPO",
      "display" : "Ordering Provider Organization",
      "definition" : "The organization the ordering provider is associated with.",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This code is broader than Referring Provider Organization (RPO); it can be used for inter and intra-organizational orders."
        },
        {
          "code" : "status",
          "valueCode" : "N"
        }
      ]
    },
    {
      "id" : "6593",
      "code" : "OS",
      "display" : "Outside Site(s) Where Observation May Be Performed",
      "definition" : "Outside Site(s) Where Observation May Be Performed",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the OM1 segment, where OM1-27 Outside Site(s) Where Observation May Be Performed has been deprecated."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Replacing OM1-27 Outside Site(s) Where Observation May Be Performed"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6594",
      "code" : "PB",
      "display" : "Packed by",
      "definition" : "Packed by",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6595",
      "code" : "PH",
      "display" : "Pharmacist",
      "definition" : "Identifies the person taking responsibility for the prescription dispense",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the RXE segment, where RXE-14 Pharmacist/Treatment Supplier's Verifier ID has been marked for backwards compatibility only."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Replaces RXE-14 Pharmacist/Treatment Supplier's Verifier ID"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6596",
      "code" : "PI",
      "display" : "Primary Interpreter",
      "definition" : "Primary Interpreter",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6597",
      "code" : "PO",
      "display" : "Performing Organization",
      "definition" : "Performing Organization",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6598",
      "code" : "POMD",
      "display" : "Performing Organization Medical Director",
      "definition" : "Performing Organization Medical Director",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the OBX segment, where OBX-25 Performing Organization Medical Director has been marked for backwards compatibility only"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6599",
      "code" : "PP",
      "display" : "Primary Care Provider",
      "definition" : "Primary Care Provider",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6600",
      "code" : "PPH",
      "display" : "Patient Preferred Pharmacy",
      "definition" : "Pharmacy the patient would prefer to use for any future medication orders.",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "When a patient registers, this allows a system to indicate the default pharmacy to which the provider should send prescribed medication orders."
        },
        {
          "code" : "HL7usageNotes",
          "valueString" : "Most likely to be used in ADT messages for outpatient care."
        },
        {
          "code" : "status",
          "valueCode" : "N"
        }
      ]
    },
    {
      "id" : "6601",
      "code" : "PRI",
      "display" : "Principal Result Interpreter",
      "definition" : "Identifies the person responsible for interpreting the results of the study/test",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the OBR segment, where OBR-32 Principal Result Interpreter has been marked for backwards compatibility only."
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6602",
      "code" : "RCT",
      "display" : "Results Copies To",
      "definition" : "Results Copies To",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6603",
      "code" : "RHP",
      "display" : "Referring Health Professional",
      "definition" : "The Health Professional who refers the patient.",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "N"
        }
      ]
    },
    {
      "id" : "6604",
      "code" : "RIE",
      "display" : "Re-Identification Entity",
      "definition" : "Organization, person or device that has the authority to assign a specimen identifier.",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "N"
        }
      ]
    },
    {
      "id" : "6605",
      "code" : "RO",
      "display" : "Responsible Observer",
      "definition" : "Responsible Observer",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the OBX segment, where OBX-16 Responsible Observer has been marked for backwards compatibility only"
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "OBX-16 Responsible Observer"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6606",
      "code" : "RP",
      "display" : "Referring Provider",
      "definition" : "Referring Provider",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the PV1 segment, when more information about PV1-8 Referring doctor is desired."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "PV1-8 Referring doctor"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6607",
      "code" : "RPO",
      "display" : "Referring Provider Organization",
      "definition" : "The Provider Organization that refers the patient.",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "N"
        }
      ]
    },
    {
      "id" : "6608",
      "code" : "RT",
      "display" : "Referred to Provider",
      "definition" : "Referred to Provider",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6609",
      "code" : "SB",
      "display" : "Send by",
      "definition" : "Send by",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6610",
      "code" : "SC",
      "display" : "Specimen Collector",
      "definition" : "The person that collected the specimen.",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the OBR segment, where OBR-10 Collector Identifier, when intended to convey person information, has been marked for backwards compatibility only"
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "OBR-10 Collector Identifier"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6611",
      "code" : "TL",
      "display" : "To Location",
      "definition" : "Describes the location (coordinates) of the specimen/container in the previous holder / storage equipment after the move or the geographical location to which the specimen/container was moved.",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "N"
        }
      ]
    },
    {
      "id" : "6612",
      "code" : "TN",
      "display" : "Technician",
      "definition" : "Technician",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the OBR segment, where OBR-34 Technician has been marked for backwards compatibility only"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6613",
      "code" : "TR",
      "display" : "Transcriptionist",
      "definition" : "Transcriptionist",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the OBR segment, where OBR-35 Transcriptionist has been marked for backwards compatibility only"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6614",
      "code" : "VP",
      "display" : "Verifier (Verifying Person)",
      "definition" : "Identifies the person verifying the dispense / a step in the dispense process / verifying the treatment corresponds to the order",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This role is used in the PRT associated with the ORC segment, where Replaces ORC-11 Verified By has been marked for backwards compatibility only"
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Replaces ORC-11 Verified By"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6615",
      "code" : "VPS",
      "display" : "Verifying Pharmaceutical Supplier (not sure how to dissect Pharmacist/Treatment Supplier's Verifier ID)",
      "definition" : "Verifying Pharmaceutical Supplier (not sure how to dissect Pharmacist/Treatment Supplier's Verifier ID)",
      "property" : [
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "RXE-14 Pharmacist/Treatment Supplier's Verifier ID"
        },
        {
          "code" : "HL7usageNotes",
          "valueString" : "Use of this code is deprecated; depending on the role of the person use either PH or VP."
        },
        {
          "code" : "status",
          "valueCode" : "D"
        }
      ]
    },
    {
      "id" : "6616",
      "code" : "VTS",
      "display" : "Verifying Treatment Supplier (not sure how to dissect Pharmacist/Treatment Supplier's Verifier ID)",
      "definition" : "Verifying Treatment Supplier (not sure how to dissect Pharmacist/Treatment Supplier's Verifier ID)",
      "property" : [
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "RXE-14 Pharmacist/Treatment Supplier's Verifier ID"
        },
        {
          "code" : "HL7usageNotes",
          "valueString" : "Use of this code is deprecated; depending on the role of the person use either PH or VP."
        },
        {
          "code" : "status",
          "valueCode" : "D"
        }
      ]
    },
    {
      "id" : "6617",
      "code" : "WAY",
      "display" : "Waypoint",
      "definition" : "Waypoint",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "6618",
      "code" : "WAYR",
      "display" : "Waypoint Recipient",
      "definition" : "Waypoint Recipient",
      "property" : [
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    }
  ]
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.